A basement floor is moisture, not decorating
A basement floor is a moisture question wearing a decorating question’s clothes. Concrete sitting on ground holds and passes water vapour for years, and the only evidence a flooring manufacturer accepts is an in-situ relative humidity test to ASTM F2170. That means a probe drilled to forty percent of the slab thickness where the slab dries from one side, or twenty percent from each side where it dries from two, left a minimum of twenty four hours to equilibrate before anyone reads it. A surface meter waved over the concrete is not that test and will not support a warranty claim. Once the number is in, the product list writes itself: resilient, vinyl and LVT sit around seventy five to eighty percent maximum, wood is typically capped at seventy five, epoxy and coatings want under seventy five, and carpet is the most tolerant at eighty five or less. Manufacturer specifications override all of those and vary, so we read the actual data sheet for the actual product.